The linear mini actuator with plastic body, MINILAT series, is suitable for simple applications; the extremely compact size (L27,5xH48xD60 mm) make it a suitable product for systems where space is an indispensable prerogative.
Suitable for occasional movements, where the required thrust loads do not exceed 100 N.
Model |
Voltage (D.C) |
No Load Speed (mm/sec) |
Max Load Speed (mm/sec) |
No Load Current (A) |
Nominal Current (A) |
Nominal Load (N) |
---|---|---|---|---|---|---|
MINILAT 0.3A 1/12 | 12 | 14 | 7 | 0.1 | 0.2 | 5 |
24 | 28 | 14 | 0.1 | 0.4 | 10 | |
MINILAT 0.3A 1/27 | 12 | 7 | 3.5 | 0.1 | 0.2 | 10 |
24 | 14 | 7 | 0.1 | 0.4 | 20 | |
MINILAT 0.3A 1/60 | 12 | 3 | 1.5 | 0.1 | 0.2 | 20 |
24 | 6 | 3 | 0.1 | 0.4 | 40 |
Model |
Voltage (D.C) |
No Load Speed (mm/sec) |
Max Load Speed (mm/sec) |
No Load Current (A) |
Nominal Current (A) |
Nominal Load (N) |
---|---|---|---|---|---|---|
MINILAT 0.6A 1/12 | 12 | 20 | 10 | 0.2 | 0.4 | 7 |
24 | 40 | 20 | 0.2 | 0.8 | 14 | |
MINILAT 0.6A 1/27 | 12 | 10 | 5 | 0.2 | 0.4 | 15 |
24 | 20 | 10 | 0.2 | 0.8 | 30 | |
MINILAT 0.6A 1/60 | 12 | 5 | 2.5 | 0.2 | 0.4 | 30 |
24 | 10 | 5 | 0.2 | 0.8 | 60 |
Model |
Voltage (D.C) |
No Load Speed (mm/sec) |
Max Load Speed (mm/sec) |
No Load Current (A) |
Nominal Current (A) |
Nominal Load (N) |
---|---|---|---|---|---|---|
MINILAT 1.5A 1/12 | 12 | 30 | 15 | 0.3 | 0.8 | 30 |
MINILAT 1.5A 1/27 | 12 | 15 | 7.5 | 0.3 | 0.8 | 50 |
MINILAT 1.5A 1/60 | 12 | 7 | 3.5 | 0.3 | 0.8 | 100 |
General Notes:
General tolerances on table values: +/- 20%
Some models only available at 12 VDC (see table)
Operating temperature: -20°C / +85°C
Encoder (Hall effect) and thermal protection on request